Bathroom radiator, LINE model, measurements: 800x600x65mm
(water connection 560mm) heating power:
297W – at temperatures: 75°C/ 65°C/ 20°C (*)
372W – at temperatures: 90°C/ 70°C/ 20°C (*)
* water powering the radiator/water at the output from the collector of the radiator/the temperature of the surroundings
The radiators are made of noble acid-resistant stainless steel – satin (1.4301 grade according to DIN). The radiators have a unique system that masks the upper bleeding valves/blank covers, which gives them even more individualistic look and exclusive characteristics.
Our radiators colouristically match all colours of tiles or paints that you may use I your bathrooms giving them unique and luxury look. The LINE range radiators are especially recommended to well lit bathrooms with a dominance of straight lines and edges, and sanitary ware considered modern and avant-garde, with delicate, fair colour and geometrical design arrangement.
With each radiator, you will get a free agent for stainless steel care by WÜRTH.
Technical specification
A table of selection of heating powers for LINE GL/800 – a steel central heating radiator.
|
ΔT, [st. C] |
0 |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
|---|---|---|---|---|---|---|---|---|---|---|
|
30 |
159 |
165 |
172 |
178 |
185 |
192 |
198 |
205 |
212 |
219 |
|
40 |
226 |
233 |
240 |
247 |
254 |
261 |
268 |
275 |
283 |
290 |
|
50 |
297 |
304 |
312 |
319 |
327 |
334 |
342 |
349 |
357 |
364 |
|
60 |
372 |
379 |
387 |
395 |
402 |
410 |
418 |
426 |
434 |
441 |
An average temperature difference ΔT is determined by the formula: Δ T=(t1+t2)/2 – tr
Where :
t1 – temperature of the water powering the radiator [st. C]
t2 – temperature of the water flowing from the radiator [st. C]
tr – temperature of the air in the heated room [st. C]
NORMAL CONDITIONS
t1 = 75 [st. C]
t2 = 65 [st. C]
tr = 20 [st. C]
for Δ T = 50 [st. C]
AN EXAMPLE OF FINDING IN A TABLE HEATING POWER OF A RADIATOR FOR CONDITIONS OTHER THAN NORMAL.
Assumption:
t1 = 83 [st. C]
t2 = 67 [st. C]
tr = 18 [st. C]
Δ T = (83+67)/2 - 18 = 57 [st. C] the value Δ T = 57 [st. C] the heating power from the table is 349 W.