LINE GL/1200

Line GL 1200

Bathroom radiator, LINE model, measurements: 1200x600x65mm

(water connection 560mm) heating power:
491W – at temperatures: 75°C/ 65°C/ 20°C (*)
613W – at temperatures: 90°C/ 70°C/ 20°C (*)
* water powering the radiator/water at the output from the collector of the radiator/the temperature of the surroundings

The radiators are made of noble acid-resistant stainless steel – satin (1.4301 grade according to DIN). The radiators have a unique system that masks the upper bleeding valves/blank covers, which gives them even more individualistic look and exclusive characteristics.

Our radiators colouristically match all colours of tiles or paints that you may use I your bathrooms giving them unique and luxury look. The LINE range radiators are especially recommended to well lit bathrooms with a dominance of straight lines and edges, and sanitary ware considered modern and avant-garde, with delicate, fair colour and geometrical design arrangement.

With each radiator, you will get a free agent for stainless steel care by WÜRTH.

Line GL 1200 Line GL 1200 Line GL 1200

Technical specification
A table of selection of heating powers for LINE GL/1200 – a steel central heating radiator.

ΔT, [st. C] 0 1 2 3 4 5 6 7 8 9
30 257 268 278 289 300 312 323 334 345 357
40 368 380 391 403 415 427 438 450 462 474
50 487 499 511 523 536 548 561 573 586 598
60 611 624 637 650 662 675 688 702 715 728

An average temperature difference ΔT is determined by the formula: Δ T=(t1+t2)/2 – tr
Where:

t1 - temperature of the water powering the radiator [st. C]
t2 - temperature of the water flowing from the radiator [st. C]
tr - temperature of the air in the heated room [st. C]

NORMAL CONDITIONS
t1 = 75 [st. C]
t2 = 65 [st. C]
tr = 20 [st. C]
for Δ T = 50 [st. C]

AN EXAMPLE OF FINDING IN A TABLE HEATING POWER OF A RADIATOR FOR CONDITIONS OTHER THAN NORMAL.
Assumption:

t1 = 83 [st. C]
t2 = 67 [st. C]
tr = 18 [st. C]
Δ T = (83+67)/2 - 18 = 57 [st. C] the value Δ T = 57 [st. C] the heating power from the table is 573 W